What this test observes
A polariscope places the specimen between a lower polariser and an upper analyser. Observations during rotation help distinguish optical behaviour, while strain, aggregates, twinning and viewing direction can complicate the result.
Underlying property: Optical character and polarisation.
Parts and setup
- Identify the light source, lower polariser, transparent stage and upper analyser.
- With the stage empty, cross the two polars to obtain a dark field.
- Place a sufficiently transparent specimen on the stage and rotate it through a full turn, observing the specimen against the field.
- Repeat in another direction if the result is ambiguous. Record whether changes affect the whole specimen or form irregular patches.
Explore the labelled polariscope in 3D
Follow the light upwards through the lower polariser, specimen and upper analyser. Rotate the specimen independently of the analyser; add the conoscope to locate the accessory used for interference figures.
Preparing the 3D instrument…
Choose a part to inspect.
Rotate the stage and compare the observation below. The crossed filters remain fixed during a specimen test.
Make an observation
Interpretation and limitations
An ideal unstrained isotropic specimen remains dark. An anisotropic specimen in a suitable direction generally alternates light and dark four times during a full turn. Along an optic axis, it can remain dark. Aggregates may remain light; strain may give patchy anomalous illumination. No single dark view proves isotropy, and a strain pattern does not by itself establish double refraction.
Dark throughout: an unstrained isotropic stone, an anisotropic stone viewed along an optic axis, or insufficient transmitted light. Reorient and check transparency.
Four extinctions: the ordinary anisotropic response in a suitable direction.
Persistent or patchy light: an aggregate or anomalous strain response needs further observation; brightness alone does not identify a material.
From rotation to interference figures
A conoscope is a small strain-free sphere held above the stone and below the analyser. After locating a suitable viewing direction near an optic axis, it helps reveal an interference figure. A fleeting coloured flash can help locate that direction.
The dark brushes are isogyres, the coloured fringes isochromes, and an optic-axis point a melatope. A simple light/dark rotation test does not determine optic sign. That needs an appropriate interference figure and additional work with a correctly oriented retardation plate or wedge.
Check your understanding
Answer each question before opening its explanation.
1. What should the empty field look like with crossed polars?
Dark: the analyser blocks light transmitted by the lower polariser.
2. Why repeat a dark observation in another direction?
An anisotropic specimen viewed along an optic axis can remain dark.
3. How does anomalous strain complicate interpretation?
It can produce patchy illumination in a nominally isotropic material, so a light patch alone does not establish ordinary double refraction.
4. Does an opaque stone remaining dark prove isotropy?
No. The transmitted-light test requires enough light to pass through the specimen.
5. What is the conoscope used for?
It helps observe interference figures near an optic-axis direction. A basic crossed-polars rotation alone does not establish optic sign.